MODEL
|
7440
|
AC WITHSTAND VOLTAGE
|
Output Rating
|
5KVAC/40mA
|
|
Range
|
Resolution
|
Accuracy
|
Output Voltage,ACV
|
0 - 5000
|
1
|
±(2% of setting + 5V)
|
Output Frequency
|
50Hz/60Hz ±100ppm, User Selection
|
Output Waveform
|
Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5
|
Output Regulation
|
± (1% of output + 5V), From no load to full load
|
SETTINGS
|
Hi-Limit AC
Current, mA
|
0-40.00
|
Resolution : 0.01, Accuracy : ±(2% of setting + 3counts)
|
Lo-Limit AC
Current, mA
|
Range : 0 - 9.999
|
Resolution : 0.001, Accuracy : ±(2% of setting + 3counts)
|
Ramp Time, second
|
0.1 - 999.9
|
0.1
|
±(0.1% + 0.05sec)
|
Dwell Time, second
|
0, 0.3 - 999.9
(0=continu)
|
0.1
|
Arc Detection
|
1 - 9 ranges (9 is the most sensitivity)
|
AC Current Offset,
mA
|
0 - 2.000 or Auto Set
|
DC WITHSTAND VOLTAGE
|
Output Rating
|
6KVDC/9999mA
|
Output Voltage, DCV
|
0 - 6000
|
1
|
±(2% of setting + 5V)
|
Output Ripple
|
<5%(6KV/9999µA at Resistive Load)
|
SETTINGS
|
Hi-Limit DC Current, µA
|
0 - 9999
|
1
|
±(2% of setting + 3counts)
|
Lo-Limit DC Current, µA
|
0 - 999.9
|
0.1
|
±(2% of setting + 3counts)
|
Ramp Time, second
|
0.1 - 999.9
|
0.1
|
±(0.1% + 0.05sec)
|
Dwell Time, second
|
0, 0.4 - 999.9
(0=continu)
|
0.1
|
Arc Detection
|
1 - 9 ranges (9 is the most sensitivity)
|
DC Current Offset, mA
|
0 - 200.0 or Auto Set
|
Ramp High Current
|
ON/OFF, User Selection
|
Charge – Low ,Current, µA
|
0 - 350.0 or Auto Set
|
Discharge Time
|
< 200 msec
|
INSULATION RESISTANCE
|
Output Rating
|
1KVDC/9999MΩ
|
Output Voltage, DCV
|
100 - 1000
|
1
|
±(2% of setting + 3V)
|
Hi-Limit Resistance, MΩ
|
0, 1 - 9999 (0=OFF)
|
1
|
±(2% of setting+2counts)
at 500-1000VDC, 1 -1000 MΩ
|
±(8% of setting+2counts)
at 500-1000VDC, 1000 -9999 MΩ
|
Lo-Limit Resistance, MΩ
|
1 - 9999
|
1
|
±(8% of setting+2counts)
at 100-500VDC, 1 -1000 MΩ
|
Delay Time, second
|
0, 0.5 - 999.9
(0=continu)
|
0.1
|
±(0.1% + 0.05sec)
|
Charge – Low
Current, µA
|
0 - 3.500 or Auto Set
|
GROUND BOND
|
Output Rating
|
30A/600mΩ, 8V
|
Output AC Current, A
|
3.00 - 30.00
|
0.01
|
± (2% of setting +3 counts)
|
Output AC Voltage, V
|
3.00 - 8.00
|
0.01
|
± (2% of setting +3 counts) at Open circuit
|
Output Frequency
|
50Hz/60Hz ±100ppm, User Selection
|
SETTINGS
|
Hi-Limit Resistance, mΩ
|
0 – 150
(3 - 30A)
|
1
|
± (2% of setting +2 counts)
|
Lo-Limit Resistance, mΩ
|
0 - 600 (3 - 10A)
|
Lead Resistance
Offset, mΩ
|
0 -200
|
1
|
± (2% of setting +2 counts)
|
Dwell Time, second
|
0.5 - 999.9s (0=continu)
|
0.1
|
±(0.1% + 0.05sec)
|
MEASUREMENT
|
AC/DC Voltage, KV
|
0 - 6.00
|
0.01
|
±(1.5% of reading + 1count)
|
DC Voltage, V (IR)
|
100 - 1000
|
1
|
±(1.5% of reading + 3V)
|
AC Current Range,
mA
|
0-3.500
|
0-3.500
|
0-3.500
|
0-3.500
|
0-3.500
|
3.00-30.00
|
3.00-20.00
|
3.00-30.00
|
3.00-40.00
|
3.00-40.00
|
AC Current, Resolution, mA
|
0.001/0.01
|
AC Current, Accuracy, mA
|
± (2% of reading + 3counts)
|
DC Current Range, µA
|
0-350.0
|
0.1
|
± (2% of reading + 3counts)
|
300 - 3500
|
1
|
3000-9999
|
10
|
AC Current, A (GB)
|
0 - 35.00
|
0.01
|
±(2% of reading+3counts)
|
Resistance, , MΩ(IR)
|
1 - 9999
(Auto Range)
|
0.001
0.01
0.1
1
|
±(8% of reading+2counts)
at 100-500VDC,
1--1000 MΩ
±(8% of reading+2counts)at 500-1000VDC,
1000 -9999 MΩ
±(8% of reading+2counts)
at 100-500VDC,
1 -1000 MΩ
|
Resistance, mΩ(GB)
|
0 - 600
|
1
|
±(2% of reading+2counts)
|
GENERAL
|
Input Voltage AC
|
115/230Vac±15%, 50/60Hz ± 5%, Fuse 5A Slow for 7410/7412 model, 6.3A Slow for 7420/7430/7440 model
|
PLC Remote Control
|
Input : Test , Reset , Memory1.2.3
Output : Pass , Fail , Processing
|
Memory
|
50 memories, 8 steps/memory
|
Display
|
20×2 LCD with back light
|
Key Lock
|
To prevent unauthorized alteration of the test Parameters
|
Calibration
|
Build-in software and external calibrated meters
|
Alarm Volume
Setting
|
Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume.
|
Rear Panel Output
|
YES
|
External Scanner
|
YES
|
Smart GFI
|
YES
|
Analog Meter
|
YES
|
RS232 Interface
|
YES
|
TUV-GS listed
|
YES
|
CE Compliance
|
YES
|
Environment
|
0-40℃, 20-80%RH
|
Dimension (W×H×D)
|
430×133×500(mm)
|
Net Weight
|
22Kg
|
STANDARD ACCESSORIES
|
Power Cord(10A)
|
×1
|
Fuses
|
×2 (Including a spare contained in the fuse holder)
|
Hipot Test Lead ,
1.5m(1101)
|
×1
|
Return Test Cable
(1102)
|
×1
|
Hipot Return Lead ,
1.8m(1103)
|
×1
|
Ground Bond Return Lead 30A ,1.5m(1104)
|
×1
|
RS232 Link Cable
1.5m(1130)
|
×1
|
|
|
|
|
|
|
|